Live
Kjøpshjelp
Kontokunde
|
Vis priser:
eks moms
inkl moms
MOBIL
Bluetooth headset
Mobilheadset kontor - mono
Mobilheadset kontor - duo
Original handsfree
KONTOR
Trådløse - mono
Med ledning - mono
CALL CENTER
Trådløse - duo
Med ledning - duo
VoIP
INDUSTRI
Bluetooth headset
Med ledning
PMR headset
DECT system
Adaptere & kabler
Tilbehør
TILBEHØR
Headset kabler
Headset reservedeler
Adapteroverganger
DECT svarmoduler
Vekslingsbokser
Forsterkere
Annet
Headset batterier
IP TELEFONSYSTEM
Call Manager
SIP system - bordapparater
SIP system - trådløse telefoner
SIP system - softphone
IP Fax
VoIP tilbehør
TELEFONER
Konferansetelefoner
SIP - bordtelefoner
SIP - trådløse telefoner
SIP - softphone
SIP - DECT servere
Analoge telefoner
Mobil telefoner
ISDN telefoner
Industri telefoner
Tilbehør
MER..
Diktafoner
Headphones
Diktafoner tilbehør
Mobil tilbehør
Dect headset
Kampanjer
Target 7050CC Duo UNC
899.-
1.599.-
Plantronics CS361N
2.390.-
Plantronics CS 60
2.190.-
Nyheter
Aastra DT432 ATEX
6.790.-
Gaitronics Hygeia 4 - Cleanroom phone
15.900.-
Gaitronics Auteldac 4 uten taster - Atex
9.560.-
Gaitronics Hygeia 4 - Cleanroom phone
Produsent:
GaiTronics
Varekode :
HYG-4
Pris:
15.900.-
Antall:
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
Leveres umiddelbart
Produktark
Produktbeskrivelse
Hygeia Isolat telefon / Steril telefon (Med glatt overflate for sterile og støvfrie miljøer) Standard Analog og SMART Analog versjoner. Også kjent som Sykehustelefon, Operasjonsromtelefon og Laboratorietelefon.Midt i blinken for matvareprodusenter der det er mye fuktighet og strenge krav til bakteriefritt miljø og mye renhold.
Hygeia 4
Hands Free Sterile Area Telephone
• Full key pad
• Flat membrane fascia,
resists contamination
• Hands free operation (VOX)
• DTMF/LD dialling
• Audio-visual ring indication
• REN 1
• CE Compliant
• Flush or surface mounting
• Volume adjust on
installation
The Hygeia is a fully electronic telephone that
incorporates many features found on modern
commercial telephones. It provides hands-free
loudspeaking communication facilities, as
intercoms PBX switching, or coupled direct to
the public telecom network.
Hygeia is a flush or surface mounted unit
incorporating a flat membrane operating
panel. When installed with suitable interface
sealants, a very high IP water resistant rating
can be achieved.
The operating membrane is an impermeable
multilayer chemically inert polyester.
Incoming calls are indicated by a flashing LED
beacon and audible warble tone. To aid
intelligibility, a volume control button is
provided for noisy environments.
Call termination can either be through button
depression, automatic time out or remote
command.
Ringer operation is selectable either at
installation or as remote programming.
Hygeia can be configured to be fully
compatible with most PABX’s or PTT
networks. Loop disconnect (LD) and tone
dialling (DTMF) systems are remotely
selectable, as are recall systems, timed break
recall (TBR) and earth loop recall (ELR).
Available as 18 button with 2 memory keys
and volume (VOL) button.
TECHNICAL SPECIFICATION
Speech:
Tested to the CTR21 specification.
Voice-switched (VOX) semi-duplex operation.
Additional half-duplex mode controlled remotely (optional local
push-to-talk button)
Send & Receive levels remote programmable (1dB step)
Receive volume control button(s) adjusts level by +/- 6dB
Call timeout programmable from 1 to 42 minutes
Remote switch-off capability
Euro-wide network matching (factory set)
Dialling Data:
LD (pulse dialling) : 66:33, 10 ips, 800ms IDP
DTMF: 100ms to ITU-T Q23
Recall: TBR (Timed Break Recall),100ms or ELR (Earth Loop
Recall)
Other formats (factory set):
LD: 60:40, 10ips, 500ms / 800ms IDP
DTMF: 50ms
TBR: 300ms or 600ms
Full keypad with 2 memories, Recall and Volume button.
Safety: Tested to EN41003 and EN60950.
Ringing and Remote Maintenance:
Dual tone ringing through loudspeaker >75 dB @ 1m REN 1.
Auto-answer for remote programming: 0 to 15 rings.
Speech disabled during remote programming: call cleared
down in favour of user dialling.
Sensing: Remote sensing of network loop current (2.5 mA
resolution) and power-supply connection.
Power Supply: Regulated power supply required 9-12Vdc
@ 500mA (included).
Memory Retention (autodiallers):
E2 PROM - 10 year life.
Temperatures:
Operating: -20° C to +55° C
Storing: -40° C to +70° C
Relative Humidity: Up to 95% (non-condensing).
Weather Resistance: Up to IP65 dependent on installation.
Please call for advice on application.
Casing Material: Front face plate membrane is an
impermeable multilayer chemically inert polyester.
Colour: White with blue printing
Weight: 1.1kg (3kg with backbox)
Overall: 352H X 181W X 48D mm
Fixing: 307H X 166W mm CRS
Cut out: 275H X 100W mm
ORDER CODE
Hygeia with back box
028-02-1408-90A
no back box
028-02-1408-900
This mark indicates
compliance with the
following directive;
R&TTE Directive 1999/5/EC
Optional Induction Loop for hearing impaired
This mark indicates compliance for inductively coupling to
Hearing Aids having a `T' switch position
Tested to ETS 300-381 and in accordance with ITU-T P37
Spør kundeservice!